Acessórios de Conexão
Sturdy case with foam insert for accessories for tests according to W 400-2.
The scope of delivery includes the following items:
- 1x test head HANS
- 2x hook spanner
- Special O-ring grease
- 1x hose Hyd16 2m Geka-S5020N
In the foam insert there is also space for the following optional items:
1x EDS2-V 1-42l/min
1x EDS2-V 4-160 l/min
1x control manometer 10 bar
1x control manometer 25 bar
1x Flow reducer DWZ/EDS2-VP max: 60 bar
and equipped with quick couplings and protective caps.
In contrast to the HEINZ specimen, this specimen has two ball valves with quick couplings 5010
and one quick coupling 2510 without ball valve.
A screw coupling -VA- is provided for connecting an external pressure sensor of the smart memo.Connection adapter 1 inch external thread, including pressure reducer and integrated valve for connecting the Mobile Gas Flare M to gas pipes.
- Integrated pressure reducer for restricting the inlet pressure at the mobile gas flare (max. 1bar)
- Integrated shut-off valve for safe gas inlet and flow restriction
- Series 21 coupling and screw coupling for connecting a pressure or concentration measuring device
- 1" ET on the inlet side, Camlock coupling DN25 on the outlet side
- max. pressure 16 bargas hose, length 10 m for Mobile Gas Flare M
NBR, both sides Camlock Adapter. Coupling DN 25 on one side,
nipple DN 25 on the other, max. pressure 16 bar- drain hose for use with the test head HANS and EDS2-V
- nominal diameter DN16 for low pressure loss and optimal flow rate
- Geka coupling on one side, nipple S 5020 on the other sidegas hose, length 5 m for Mobile Gas Flare M
NBR, both sides Camlock Adapter. Coupling DN 25 on one side,
nipple DN 25 on the other, max. pressure 16 barOptional additional part to the Test head HEINZ for
carrying out water pressure tests according to W400-2.
The pressure hose of the pump and an EDS2-V can be
connected to the HEINZ at the same time via the T-piece.
Connections:
T-piece With nipple Series 5020 (Series 5000) and
2x coupling Series T 5010 with ball valve (Series 5000)Included:
- rugged outdoor case with foam insert
- testhead HANS 2 1/2" ext. thread, Pmax: 60 bar
- two hook spanner 95-100 mm
- special o-ring-grease approximatly 20g
- filling hose air DN16 x 1m
- Adapter ventilation with sound insulation
Adapter for the Mobile Gas Flare M for use in hard-to-reach blow-out units.
Connections: inlet side 1" ET with O-ring, outlet side Сamloсk coupling DN25 Gas hose DN25 with Сamloсk nipple can be connected directly.
Max. pressure 16 bar
Claw coupling with connecting nipple series 5020T-connector with camlock connections for parallel operation of two devices of Mobile Gas
Flare M
max. pressure 16 barPressure hose, gas resistant, length 3 m, NBR DN13,
one side nipple series 2520, other side claw coupling,
max. pressure 16 bar
For pressurising pipelines via test specimen HEINZPressure hose DN 20 x 10 meters for MPP 70-35
both. series 5020 plug nipple and protective capwith nipple series 5020 can be used with test body HANSCompressed air manifold DN15 with claw coupling and ball valve on the inlet side, 2 outlets with claw coupling on the outlet side for simultaneous pressurisation of pipelines, e.g. for tests according to FW 602.
Max. pressure: 16 barOptional adapter for using the v-measurement in the OLLI for the Mobile Gas Flare M.
The appropriate connecting hose for v-measurement with the OLLI (article 285076) is also
required.Hose set for use of the v-measurement in the OLLI for the mobile gas flare S and M.
On the inlet side there is a single hose connection with S20 nipple, which is plugged into a suitable coupling in the connection area of the mobile gas flare. On the outlet side, there are two hoses with S20 couplings for concentration measurement (red hose, pressure reducer 50 mbar integrated) and for pressure measurement (black hose) in the OLLI.Optional adapter for using the v-measurement in the OLLI for the Mobile Gas Flare S.
The appropriate connecting hose for v-measurement with the OLLI (article 285076) is also required.for carrying out leak tests on wastewater pipelines with the test medium air in accordance with EN1610 or DWA-A 139.
The test fitting provides all necessary connections for pressure build-up, pressure reduction, pressure measurement and pressure release of the test chamber. The test fitting can be connected to the test bottle via a compressed air hose so that the test can then be carried out from a distance.
The following connections are available:
- compressed air nipple series 26 with ball valve for pressure build-up
- safety overpressure valve with trigger pressure 300 mbar
- ball valve with silencer for pressure release
- screw coupling 1620 for connection of an EDS2-P pressure sensor
- compressed air nipple series 26 for connection to the test chamberAdapter for test head HUGO
Adapter 1 inch internal thread to 1 inch internal thread